TECHNOLOGY & SERVICE

Technology & Service Capability

From microwave RF to NMS, from on-site survey to overseas delivery — we write “what we can do” as third-party-verifiable numbers.

VERIFIABLE EVIDENCE
13Patents11Copyrights
Also High-Tech Enterprise, ISO triple system, and SRRC model approval on multiple devices
Device to system
RF front end, monitoring unit, and NMS platform are all self-developed, not bought-and-assembled
Verifiable capability
Every capability is backed by a patent number, software-copyright registration, or model approval
Acceptable delivery
Survey data, test records, and acceptance metrics archived item by item, not verbal promises
Domestic / overseas split
Two markets, two playbooks: domestic localized delivery, overseas brand & technical support
03 / TECH & SERVICE CAPABILITY

Six core capabilities, each verifiable

No adjective piling — behind every capability hangs a patent number, software-copyright registration, or model approval; verifiable and accountable

RF ENGINEERING

Microwave & RF Engineering

From component to system — we design every stage of the RF chain ourselves

  • Dual-band / multi-band BDA platform: one RF front end adapts to multiple band combinations, cutting on-site retrofit cost
  • Self-designed cross-band duplexer — isolation and rejection specs enforced to engineering red lines, not pieced together from bought modules
  • Strict non-interchangeable uplink/downlink signal extraction (uplink RF420 / downlink RF430) — eliminates reverse crosstalk and receiver damage
  • High-power linear amplification + ALC automatic level control — no drift under long full-power runs; low-noise receive chain designed to noise-figure targets
  • Structural reliability backed by patents: moisture/heat dissipation, cable management, anti-wind antenna mounting, anti-detachment data interfaces
EVIDENCE
13 utility-model patents (2 RF core + 5 structural)Cross-band duplexer ZL 2019 2 0544785.7SRRC radio-transmission equipment model approvalRoHS 2.0 compliance for all 10 certified models (IEC 62321 series)
RELATED PRODUCT LINECoveragePassivesRepeatersCertifications & compliance
Technical detail
07 / QUALIFICATIONS & IP

Every capability has a verifiable number

Patent numbers, software-copyright registrations, system certifications — originals and registration info can be verified item by item during business engagement

13Utility-Model Patents

Four clusters: RF core, structural engineering, dual-/multi-band, fiber RF — patent numbers public and verifiable

11Software Copyrights

Covering NMS platform, device monitoring, and protocol conversion; earliest developed in 2007

4 typesSystems & Model Approval

High-Tech Enterprise · ISO 9001 / 45001 / 27001 triple system · SRRC model approval on multiple devices

A CLASS4 ITEMS

Dual-band / Multi-band

One RF front end adapts to multiple band combinations

  • A dual-band BDA
    ZL 2019 2 0571755.5
  • An easily-installable dual-band BDA
    ZL 2019 2 0571817.2
  • A multi-band fiber BDA
    ZL 2019 2 0544872.2
  • An easily dis/assembled multi-band fiber BDA
    ZL 2019 2 0571816.8
B CLASS5 ITEMS

Structural Engineering

Built for tunnel, underground, and coastal humidity & high-wind mounting

  • A 350M fiber BDA with moisture-proof, heat-dissipating structure
    ZL 2019 2 0544811.6
  • A 400M fiber BDA with cable-management structure
    ZL 2019 2 0544873.7
  • A 350M fiber BDA with stable antenna mounting
    ZL 2019 2 0544874.1
  • A 400M fiber BDA with anti-detachment data interface
    ZL 2019 2 0544875.6
  • An easily-installable BDA
    ZL 2019 2 0544815.4
C CLASS2 ITEMS

RF Core

Patent backing for passives and the low-noise receive chain

  • A cross-band duplexer
    ZL 2019 2 0544785.7
  • A low-noise, heat-dissipating fiber RF BDA
    ZL 2019 2 0571785.6
D CLASS2 ITEMS

Fiber RF

Fiber BDA whole-machine architecture and remote monitoring capability

  • A fiber RF BDA
    ZL 2019 2 0571799.8
  • A communication BDA with remote working-state monitoring
    ZL 2019 2 0572057.7
SOFTWARE COPYRIGHT (11 total; private-network-related registrations excerpted)Registration numbers verifiable
  • BDA NMS Software V1.02024SR1851717
  • All-Optical Network Coverage System Monitoring Software V1.02024SR1862186
  • Kingtone GSM Digital Fiber BDA Monitoring Software V1.02010SR049131
  • Kingtone WCDMA BDA Monitoring Software V1.02010SR049117
  • Kingtone Optical Module Monitoring Software V1.02010SR049116
  • Kingtone RS485 LNA Monitoring Software V1.02010SR049135
  • Kingtone BDA Cooling System Control Software V1.02010SR049132
  • Kingtone RS485 Frequency-Select Serial-Parallel Protocol Conversion Software V1.02010SR049130
  • Kingtone RS485 Module Debugging Software V1.02010SR048606

Also available: information-security, quality-management and other system certification certificates, plus SRRC radio-transmission equipment model-approval certificates for multiple devices; upon request we can provide certificate copies and registration lookup paths during business engagement.

04 / SERVICE & DELIVERY

One system, two markets, two service radii

Domestic: localized delivery & spare-parts support; overseas: own-brand export & English technical support — not one playbook for both

Domestic MarketCHINA MARKET
LOCAL DELIVERY

Localized delivery across 14 industry scenarios

  • 7000+ projectsHotels, hospitals, campuses, transport hubs, smart manufacturing, energy & chemical, tunnels, emergency — all scenarios landed
  • Survey-firstMeasure before design; provide constructable plan by building structure and interference environment
  • Local spare parts & responseDevices and passives locally supplied; faults quickly recovered by swap
  • Maintenance subscription optionalS200 management + remote inspection — hand the system to a party that owns it long-term
Overseas MarketGLOBAL MARKET
EXPORT SUPPORT

Own-brand export with English technical support

  • Brand structureKINGTONE is the export brand and part of the company name; JIMTOM is the registered product mark that current certificates are issued under
  • Trademark statusJIMTOM registered in China and via the Madrid system (IR 1446419); KINGTONE filed in China, under examination
  • English technical docsSpecs, drawings and acceptance standards delivered in English; engineers can deploy directly
  • Remote supportRemote commissioning and technical response, with spare-parts strategy and cross-time-zone communication
  • Certification registerCE (RED), RoHS 2.0, SRRC, ISO 9001/45001/27001 — full register with issuers and reference numbers at /certifications/
DELIVERY PROCESSA six-step closed loop from survey to O&M; every step has a deliverable
  1. 01
    Survey
    SURVEY

    Building structure, existing network, interference-source check — output survey record

  2. 02
    Design
    DESIGN

    Link budget, coverage simulation, equipment selection and topology diagram

  3. 03
    Supervise
    SUPERVISE

    Cable routing, device installation, on-site process-standard control

  4. 04
    Commission
    COMMISSION

    Power and gain adjustment, isolation and interference retest

  5. 05
    Accept
    ACCEPT

    Field strength, call quality, latency and other metrics archived item by item

  6. 06
    Operate
    OPERATE

    NMS management, remote inspection, fault response and spare-parts support

FREQUENCY & STANDARD

Frequency and standard matrix

Select by band and standard; confirm licensing conditions before discussing equipment configuration

BandStandard / roleTypical scenariosLicensing & notes
VHF 136–174 MHzVHF conventional radioForestry, water conservancy, coastal, field operationsSpectrum licence required
350 MHzTrunking / public safetyPublic safety, emergency command & dispatchSpectrum licence required
400–470 MHzUHF conventional / DMR digitalHotel, hospital, campus, factory, parking, tunnelMain band; SRRC-approved models
800 MHzTrunked private network (TETRA / trunking)Metro, port & terminal, large plantsProject-based configuration
1.4 GHz / 1.8 GHzLTE / 5G private networkIndustrial campus, IIoT, smart factorySpectrum licence held by customer
2.6 GHz / 3.5 GHz5G NR private networkPlants, venues, mines, portsIndustry private network

Scope: private networks only

KINGTONE supplies private radio and private LTE/5G coverage — networks that the customer owns and operates. Coverage of public-carrier cellular service, and consumer-grade plug-in amplifiers, are outside our scope of supply. A private network is engineered from a link budget: band, output power, antenna isolation and feeder loss are calculated for the site rather than selected from a gain figure on a box.

Fiber-optic BDA / fiber remote

Buildings and utility tunnels where fiber can be laid: long reach, stable latency, digital and analog fiber modes both supported.

Wireless broadband repeater

Sites where cabling is impractical or across separate buildings: no fiber needed, the link bridges head-end and remote units over the air.

ICS interference cancellation

Used when a co-channel signal already exists on site. Cancellation better than 30 dB removes the root cause of self-oscillation.

Leaky cable / leaky feeder

Linear enclosed spaces such as tunnels, utility galleries and metro lines: uniform radiation along the route, no coverage holes.

Zoned / floor-by-floor coverage

High-rise buildings split into coverage units by floor or fire compartment for isolation, expansion and fault localisation.

Micro-power / pico indoor coverage

Spot fill for small dead zones; the micro-power platform already holds SRRC model approval.

Antenna & feeder engineering

Antenna selection, isolation calculation and feeder insertion-loss budget are handed over together, with VSWR and insertion-loss test records.

Remote NMS & local control

Both remote network monitoring and local on-site control are supported; once connected to S200 NMS, multi-brand devices can be managed together.

Deep dive: the all-optical network coverage system

Fibre replacing coax: the AU / MU / EU / RU architecture, uplink and downlink chains, uplink noise control, a three-way comparison and the CV410 / Cellular Mate product matrix — with figures.

Read the encyclopedia entry
SELECTION MATRIX

Analog, DMR digital or PoC: select by constraints, not by technical ranking

Start from three hard constraints — operation without a network, basements and tunnels, back-office management — then discuss cost; the table is qualitative and the radio count follows site survey and link budget

ConstraintAnalogDMR digitalPoC over cellular
Coverage sourceSelf-built: direct mode + repeaterSelf-built: repeater / fiber BDA / digital indoor distributionCarrier base stations, no private frequency needed
Works without a networkYesYesNo, relies on the carrier network
Basement / tunnelNeeds self-built fill-in; few analog optionsMature: fiber BDA plus leaky feederDepends on whether carrier indoor coverage exists
Voice paths per repeater1 (single-frequency simplex)2 (two-slot TDMA)Billed per concurrent session, no fixed limit
Location / recording / dispatchRequires extra logging equipmentRequires a dispatch console or custom developmentNative, ready out of the box
Cost tierLowest system costMidLow handset cost, plus data and platform fees
Typical fitSmall sites, temporary use, very tight budgetMid-to-large sites, mines, campuses needing self-owned coverageMany scattered points, back-office management, good urban coverage

Note: analog and DMR are both self-built networks. Coverage depends on repeater position, antenna isolation and the link budget, not on the nameplate power rating. PoC availability depends on carrier coverage in the target area; for emergency and safety-critical sites, keep a fallback plan for network outages.

ENGINEERING NOTES

Six solution questions, worked through: scene, parameters, acceptance, boundary

Each entry carries verifiable figures and an explicit reverse condition. These are design targets and calculation methods, not measured project results.

Public-network PoC or conventional radio: which suits a construction site?

Scene sizing
Typical site: 10,000–30,000 m² of work area, heavy shadowing from tower cranes and scaffolding, three to five contractor crews on air at once, a 6–24 month programme. Temporary power and temporary offices mean there is usually no in-building distribution system to lean on.
Design parameters
Start with the "works without a network" test. Conventional radio (analog or DMR) uses self-owned channels and keeps working through a power or network outage; public-network PoC depends on carrier 4G/5G and only works indoors or underground where distributed antennas already exist. On sites with basements or deep excavations, a self-built repeater or BDA covers far more than a public network. On fully above-ground urban sites, PoC saves the cost of building a network.
Acceptance
Self-built acceptance: at least 95% of test points at or above −85 dBm with no continuous blind zone over 40 m. Public-network acceptance: measured reference signal received power at or above −105 dBm with working uplink; anything below that counts as uncovered and must be filled with a self-built system.
Boundary
Programmes under three months with fewer than 20 radios are simpler on PoC. Sites with explosion-proof, classified or emergency-command requirements cannot rely on a public network alone and must keep a self-built narrowband channel as the fallback.

How do you get full coverage around tower cranes with no blind spot?

Scene sizing
Crane jibs run 50–70 m with hook heights of 40–80 m; the operator cab is a steel structure that shields RF heavily. Ground banksmen, signallers and material handlers work within a 100–150 m radius, and rebar or formwork stacks add further shadowing.
Design parameters
Trade height for line of sight: mount the repeater antenna on the crane mast or an adjacent high point. Radio horizon approximates 4.12√h in km with h in metres — about 13 km at 10 m and 26 km at 40 m — then discount for shadowing and power. Inside the steel cab, add a small coupling antenna or aim a directional antenna at it; use 400–470 MHz handhelds at the jib tip rather than 2.4 GHz licence-free bands, which penetrate poorly.
Acceptance
Clear-call rate between the cab and ground control at the jib tip, the mast base and the material yard no lower than 95%; no continuous loss of contact longer than 10 s during a lift; no dropped call when handing over between cranes.
Boundary
Above 80 m hook height, lightning protection and feeder loss become the binding constraints — run fiber to mid-mast and use a short feeder from there. A single crane on a low-rise site within a 300 m radius needs no repeater at all; direct mode is sufficient.

How do you actually deploy an integrated smart-site radio and dispatch system?

Scene sizing
A typical smart site has one to three work faces, two to four tower cranes, a concrete batching area, a material yard and a project office, with 50–300 terminals. Voice, video, personnel tracking and access control all have to land on one map.
Design parameters
Build it in three layers. Sensing: DMR handsets plus location tags. Transport: self-built repeaters or BDAs, with 4G/5G available for backhaul. Platform: a dispatch console that manages everything. Voice runs on narrowband as the baseline and does not depend on the public network; video and tracking run on broadband. Crane monitoring, hoists and excavation monitoring each get a separate return path so they never compete with voice for bandwidth.
Acceptance
Dispatch call setup to terminal ring under 2 s; tracking refresh within 30 s; single-channel video return at or above 2 Mbps; voice still works when the platform side loses its network, and data backfills automatically with no lost records once it returns.
Boundary
Sites under 30 terminals that only need voice do not need a platform; repeaters with talkgroups are enough. Where the main contractor already runs a platform, integrate with it rather than standing up a second one — two sets of accounts and two sets of maintenance become an on-site burden.

Digital radio or public-network PoC: which is cheaper on a construction site?

Scene sizing
Compare on three-year total cost of ownership: 50 terminals, 20,000 m² of work area, one basement level. A digital system front-loads equipment and installation; PoC spreads cost into annual airtime and platform subscription.
Design parameters
Digital: one or two repeaters, 50 handsets and local blind-spot fill, with batteries and repairs as the only recurring cost. PoC: lower handset price but continuous per-unit airtime and platform fees. Accumulate three years of subscription and most projects land in the same order of magnitude as a self-built system; the real difference is outage tolerance and basement coverage.
Acceptance
Normalise the comparison to three years: equipment, installation, airtime and platform fees, plus maintenance labour. Then check three hard requirements one by one — works without a network, covers basements and deep excavations, needs tracking and recording — and only compare price once all three are settled.
Boundary
Crews that move between provinces and projects shorter than a year make PoC attractive, because avoiding network build outweighs the subscription. Where basements and deep excavations must stay on air through an outage, PoC cannot close the gap and a self-built system is the only answer.

Can a radio dispatch system be deployed on-premises with no public network at all?

Scene sizing
On-premises means the dispatch server, database and call recording all sit in the customer's server room or private cloud, never touching a vendor cloud. The usual requirements are: works through an outage, data never leaves the plant, accounts administered by the customer.
Design parameters
Three components, none optional. A local dispatch server, which can run on one rack server or industrial PC starting at 8 cores and 16 GB RAM. A local gateway bridging narrowband repeaters and broadband terminals so voice never crosses the public network. Local storage for recordings and location tracks, sized for 90 days of retention. Licensing is offline, with no online validation call.
Acceptance
With the WAN disconnected, dispatch, recording, tracking and alarms all remain usable. Data resides only on the customer intranet. Accounts and permissions are maintained by the customer administrator. An offline licence can be renewed 30 days before expiry without interrupting service.
Boundary
Where several sites across regions need unified dispatch and no dedicated line exists, pure on-premises loses the coordination benefit — use a hybrid of local fallback plus cloud aggregation. Buyers who only purchase handsets and need no back office do not need on-premises at all; direct mode is enough.

On-premises dispatch or cloud dispatch: which is safer for the data?

Scene sizing
The security difference is not cloud versus local, it is control: who holds the database, who can export recordings, and whether dispatch survives an outage. Common compliance requirements include 90 days of recording retention, no data leaving the intranet in classified areas, and auditable account activity.
Design parameters
On-premises: database and recordings stay on the customer intranet, transport runs over the LAN or a dedicated line, accounts can bind to the customer directory, and dispatch keeps working through an outage. Cloud: the vendor holds the data under tenant isolation, cross-region disaster recovery and zero maintenance are genuine advantages, but dispatch stops when the network does, and retention and cross-border policy are set by vendor terms.
Acceptance
Four checks: is dispatch usable with the WAN down; can recordings be exported locally in one action; can accounts bind to the customer directory; are audit logs retained for 180 days or more.
Boundary
Chains with many scattered sites and no IT operations team are better served by cloud disaster recovery and zero maintenance. Classified sites, safety-critical command centres and any requirement that data must not leave the plant force on-premises — and a "hybrid cloud" label must not be used to put core data back on the public internet.
TECHNICAL FAQ

Technical FAQ: self-oscillation, isolation, selection and loss budget

These are the questions integrators and end users ask most often at design stage — usable directly for technical handover

Why does a repeater self-oscillate, and how is it solved?

Self-oscillation comes from insufficient isolation between the donor antenna and the service antenna: the output signal is picked up again at the donor side and forms positive feedback. There are three remedies — increase the horizontal or vertical separation between the two antennas, add an isolation barrier or exploit building structure as shielding, or reduce gain and enable automatic level control (ALC). The correct approach is to calculate the isolation margin at design stage rather than tuning gain on site.

How much antenna isolation is required?

As a rule of thumb, antenna isolation must exceed the system gain by 10–15 dB to leave a stable margin. For an 80 dB system gain, isolation of at least 90–95 dB is recommended. Vertically separated mounting usually gives better isolation than horizontal, and floor slabs, parapets and lift shafts can be used as natural shielding.

Fiber-optic BDA or wireless repeater — which one should I choose?

If fiber can be laid, choose fiber: longer reach, stable latency and immunity to over-the-air interference. Only use a wireless broadband repeater where cabling is impractical — heritage buildings, road crossings, temporary sites. The two can be mixed: fiber on the trunk for quality, wireless on the last branch to save cost and time.

How many antenna points can one coverage unit serve?

It depends on the branch insertion-loss budget: from head-end output to the farthest antenna, the cumulative loss of feeder, power divider, coupler and connectors should stay within about 10 dB. For conventional 400–470 MHz indoor antennas, 4–8 antenna points per head-end is a common configuration, adjusted after on-site survey.

Can radio equipment be used in hazardous areas?

Yes, but explosion-proof models must be selected to match the hazardous-area classification. Underground mines, oil and gas fields and chemical tank farms are mandatory cases: confirm the zone classification and the explosion-proof marking before selecting equipment. Standard models cannot be substituted, and an added enclosure alone does not make a device compliant.

Which radio should a construction site or mine choose: analog, DMR digital or PoC over cellular?

Answer three questions first. Are there basements or tunnels, which decides whether a repeater must be built on site? Must the system keep working when the mobile network is down, since PoC depends on carrier coverage? Do you need location tracking, voice recording and back-office dispatch, where PoC is strongest? With good urban coverage and a back-office requirement, choose PoC. With many underground or tunnel sections and a need for self-owned coverage, choose DMR digital with a repeater or BDA. For short-term use on a very tight budget, analog is still the cheapest option. The real trade-off is coverage autonomy versus dispatch convenience.

When is a repeater or a BDA mandatory?

When direct radio-to-radio communication is blocked by floor slabs, steel structures or sheer distance. On tower cranes and high-rise sites, a repeater lifts the signal to a high point and radiates it back down. In basements, tunnels and utility galleries, a fiber-optic BDA or fiber repeater (near-end MOU plus remote-end ROU) fills the blind zone directionally, and the fiber link can reach roughly 20 km. In multi-building campuses, digital indoor distribution splits the signal across buildings instead of building a separate repeater in each one.

On a limited budget, what is the most cost-effective radio configuration for a construction site?

Split by scale. Small sites under 20 radios with no basement: analog or entry-level DMR plus one same-frequency repeater. Mid-size sites of 20 to 100 radios with tower cranes or partial basements: DMR handsets plus a duplex repeater, with local fiber BDAs for blind spots. Large or multi-building sites above 100 radios with tunnels and galleries: digital repeater plus fiber repeater or digital indoor distribution plus a dispatch console. Always survey the site before ordering: over-buying wastes money, under-buying costs more to fix later.

Does a higher repeater power always mean better coverage?

No. Coverage is set by antenna position, isolation and the link budget; excessive power actually increases the risk of self-oscillation and interference with neighbouring cells. The correct sequence is to calculate path loss and the isolation margin first, then choose the power tier and the number of antenna points. Acceptance should be based on measured field strength from a site drive test, not on the nameplate power rating.

TECHNICAL DISCUSSION

Want to discuss a specific technical solution?

Send us your scenario, building conditions, and band requirements; our technical team will provide link budget and equipment-selection advice; test data, patent, and software-copyright registration info can also be provided for verification.

WhatsAppGet a Plan