What it is — and what it is not
An all-optical network coverage system for two-way radio applies the fibre-distribution method of in-building systems (IBS / DAS) to private radio: repeaters, channelized radios or trunked base stations at the source side output RF signals; a near-end unit performs electrical-to-optical conversion; the fibre carries them over long distances at low loss; a remote unit converts back, amplifies, and radiates through antennas or optical antennas into the target area. Uplink signals return along the reverse path.
Keep the terms apart: Here "all-optical" means the transport medium of the coverage link is entirely optical fibre; electrical/optical and optical/electrical conversion still happens at both ends, and the last hop is still a radio wave. It is not the same concept as the all-optical network (AON) of optical communications, where transmission and switching remain in the optical domain with no intermediate opto-electronic conversion.
The system extends coverage only — it never adds source capacity: channel count and traffic capacity are decided by the repeaters or base stations. By signal-processing method there are two families: analog fibre repeaters (RF directly modulates the optical carrier) and digital fibre distribution systems (A/D sampling, framed transport, digital band selection and full network-element management).
Why go all-optical
Optical fibre offers low transmission loss, immunity to electromagnetic interference and a small bend radius — ideal for large building complexes, tunnels and long linear spaces. Digitisation adds independent sub-band switching, uplink squelch and cascading, so one-to-many networks are no longer bounded the same way by splitter insertion loss and uplink noise stacking.
- Conventional coax passive IBS: Feeder loss climbs with distance and frequency; cascaded dividers and couplers eat the link budget. Passive nodes cannot be monitored, so faults are traced segment by segment.
- Multi-system coexistence: When 350 MHz public safety, 400 MHz dispatch, FM broadcast, Wi-Fi and broadband private networks all enter one building, repeated cabling and isolation calculations become complex.
- IoT service admission: Cameras, environmental sensors and smart meters need their own cabling if run separately, driving up both construction cost and later operations.
- Energy and maintenance: When active-node status, optical link loss and RF power can be collected in real time, "send someone to trace the fault" becomes "locate it remotely".
System composition and architecture
Source and front end: Channelized radios / repeaters, combiners (POI), splitters / power dividers, duplexers and signal strippers. When several repeaters share one antenna system, port isolation and uplink combining are the key constraints.
Optical transport and distribution: The AU handles source access and control (cavity filters + FPGA + SDR: operating sub-band switching, filtering, intelligent detection and network adaptation). The MU converts downlink RF to optical and uplink optical to RF. The EU regenerates and amplifies the optical signal, distributes it and combines uplinks — in some form factors the EU is also the single power-intake point. The RU completes optical/electrical conversion, filtering and amplification for coverage, and can embed Wi-Fi and an edge-computing server.
Network management: A B/S-architecture OMC provides electronic-map positioning, cascaded-topology visualisation, online/offline/alarm indication, parameter sampling, remote configuration and firmware OTA upgrades; via northbound interfaces (TCP / UDP / SMS) it can manage third-party equipment or feed an external NMS.
How uplink and downlink work
Downlink: Source RF is combined, duplexed and level-adjusted into the near-end unit → electrical-to-optical conversion (analog designs directly modulate the optical carrier; digital designs sample and frame first) → fibre transport and EU distribution → remote depacketising / D/A / up-conversion → power amplification and filtering → antenna radiation.
Uplink: The antenna receives handset signals in the coverage area → the remote unit low-noise-amplifies and converts them to an uplink optical signal → fibre back to the near end → restored to RF → through splitters / strippers and the duplexer back to the source receiver. Downlink and uplink commonly share one fibre strand bidirectionally via 1310 nm / 1550 nm WDM.
Link gain, automatic level control (ALC), in-band ripple, noise figure and latency together decide coverage quality. Excessive uplink gain raises the source noise floor; uplink/downlink balance must be verified at design and commissioning.
Key techniques
| Technique | Engineering value |
|---|---|
| WDM single-fibre bidirectional E/O conversion | Low-loss reach, EMI immunity, small routing footprint; the optical link budget must reserve splitter attenuation |
| SDR and digital IF processing | Digital filtering and independent in-band sub-band switching — enable or disable services per project |
| Uplink noise suppression / uplink squelch | Contains noise stacking across parallel remotes; in analog designs the noise floor rises by 10lg(N) with remote count, digital designs only activate links carrying uplink traffic |
| Latency compensation | Digital processing adds latency; reconcile with source sync/search-window settings and coverage overlap zones |
| ALC and linear power amplification | Holds output power steady under input fluctuation, controls intermodulation and spurious emissions, protects the source and neighbouring systems |
| Multi-system combiner POI | 350 MHz public safety / 400 MHz dispatch / FM broadcast / Wi-Fi / broadband private networks share one infrastructure |
| Every element manageable | Optical link loss, optical TX/RX power and RF power sampled in real time; fault-finding moves from site walks to remote location |
| Central power and edge computing | Expansion unit takes unified power, or power is fed over the RF cable; the RU embeds edge computing and Wi-Fi to carry IoT sensing services |
Three approaches compared
| Aspect | Coax passive IBS | Analog fibre repeater | All-optical digital DAS |
|---|---|---|---|
| Transport medium | RF coaxial cable + passive components | Optical fibre (RF directly modulates the optical carrier) | Optical fibre + digital transport |
| Reach | Limited by feeder loss | Kilometre-class, nominal up to 20 km | Kilometre-class, multi-level cascading supported |
| Uplink noise | No active amplification | Noise floors stack across remotes | Digital processing + uplink squelch suppress stacking |
| Manageability | Passive nodes cannot be monitored | Near-end / remote-end monitorable | All-element status and power monitorable in real time |
| Multi-system convergence | Combining and link budget must be redone | Multi-band combining supported, isolation demanding | Independent sub-band switching eases shared infrastructure |
| Service expansion | Communications coverage only | Communications coverage only | IoT admission and edge computing can be layered on |
The Kingtone product matrix
| Product / series | Positioning and key specifications | Typical scenarios |
|---|---|---|
| CV410 all-optical network coverage system | Low power, manageable and expandable all-optical coverage form factor | Campus / buildings |
| Cellular Mate AU / MU / EU / RU | SDR independent sub-band switching; fibre replaces RF cable, dividers and couplers, optical antennas replace passive antennas; RU embeds manageable Wi-Fi and an embedded edge-computing server; micro-DAS form factor delivers 100–200 mW per band; LTE / NR with up to any 4-band combination; OMC intelligent cloud NMS | Commercial complexes / offices / underground space / multi-service convergence |
| ERRCS fibre repeater system MOU + ROU | 410–414 / 420–424 MHz, customisable; downlink 37 ± 2 dBm (5 W); maximum gain 60 ± 3 dB; optical attenuation ≤ 10 dB (including optical splitter); 1310 / 1550 nm WDM single fibre; reach up to 20 km; latency ≤ 5 μs; noise figure ≤ 5 dB; CCVIEW network management | Exhibition halls / metro / airports / large plants / tunnels |
| KT-T800-MDAS TETRA800 Micro-DAS | 806–821 / 851–866 MHz; +17 ± 2 dBm; gain +50 ± 3 dB; one EU drives up to 8 RUs; +24 V centralised remote power over pre-terminated RF cable; star topology expandable to tree | Tunnels / factories / mines / malls / basements |
| Passive components and NMS | Combiner POI (2/4/6/8 ports, isolation ≥ 35 dB), 12-cavity duplexer (isolation ≥ 85 dB, insertion loss ≤ 1.5 dB), power dividers, signal strippers; S200 NMS supports multi-brand device onboarding and monitoring | Full-chain ancillaries |
Some standards-based lines configure bands and power per project; third-party certification for some product lines is in progress — confirm against the certificate list actually available at selection time.
Typical application scenarios
Coverage-unit spacing depends on the scenario: roughly 35 m for small open rooms with partitions, 45 m for large open rooms, and about 25 m in open zones / 20 m in partitioned zones for heavily partitioned floors — keeping line of sight between units and staying near main corridors and lift lobbies.
Underground parking, basements, lift shafts, equipment rooms
Road and rail tunnels, utility galleries, metro running tunnels
Offices, hotels, venues, airport terminals — zoned floor-by-floor coverage
Large plants, chemical parks, coal mines, power plants (explosion-proof / ingress-protection requirements)
Firefighting and rescue command; bringing police and emergency radio signals into buildings
FM broadcast + 350 MHz public safety + 400 MHz dispatch + Wi-Fi + broadband private network
Design and compliance essentials
- Standards baseline: In China, GB 51348—2019 "Standard for electrical design of civil buildings" clause 20.4 defines the digital radio coverage system composition and how 350 MHz public-safety signals are introduced; DG/TJ 08—2406—2022 covers fibre repeater networking, low-power multi-point indoor layouts, per-antenna signal strength not exceeding 15 dBm and power differences between antennas within 5 dB; YD/T 4009—2022 specifies technical requirements for 5G digital indoor distribution systems.
- Frequency and type approval: Repeaters are radio-transmitting equipment: manufacture, sale and use must satisfy type approval and frequency licensing. Before a project lands, verify equipment certificates against local radio-regulatory requirements.
- Link budget: Compute edge field strength from optical link loss (including splitters), remote-unit output power, feeder and antenna losses; verify uplink balance and the latency budget.
- Redundancy and protection: Tunnels and galleries need backup fibre routes, primary/standby switchover, ingress protection (IP65 / IP67) and explosion-proofing where required; the remote power-feed method decides whether a local power point is needed on site.
- Export projects: Check applicable standards and certificate coverage: CE / RED, RoHS, EN IEC 62368-1, EN 50385 and equivalents.
Frequently asked questions
Does an all-optical system add radio channels or capacity?
No. Channel count and traffic capacity are decided by the repeaters / base stations; the coverage system only extends and distributes signals. To add capacity, add channelized radios or reconfigure the source.
Analog fibre repeater or digital all-optical DAS — how to choose?
For few coverage points, short distances, tight budgets and no NMS requirement, an analog fibre repeater still works. For many parallel remotes, multi-system combining, uplink noise control and full network-element monitoring, the digital all-optical DAS fits better. Digital designs require extra latency accounting.
Do existing radios need to be replaced?
Usually not. The coverage system operates on the existing standards and bands, so handsets stay as they are; the rework focuses on how the source is coupled, the link budget and antenna placement.
Can one system carry both radio and IoT services?
In the digital-DAS form factor, the RU provides manageable Wi-Fi access and edge computing, giving cameras, environmental sensors and smart meters an admission channel. The exact service scope follows the project configuration.
Which acceptance item is most often overlooked?
Uplink balance and noise floor, optical link loss margin, latency and coverage overlap zones, per-antenna port power, NMS alarm interlocking and remote upgrades. Write these into measurable acceptance criteria at detailed-design stage.
KINGTONE Solutions · technical encyclopedia for private radio coverage. Figures are nameplate values from product data sheets; on real projects survey results, frequency licensing and acceptance testing govern.