Underground Parking Radio Solution
Solves no-signal, security blind spots and unreachable emergency comms in residential, commercial and hospital basements.
3 common underground-parking radio problems
- 01
No basement signal:Reinforced-concrete shielding is severe; ground signal cannot reach.
- 02
Security patrol blind spots:Guards in the garage cannot reach the control room, hurting emergency response.
- 03
Fire rescue blocked:In fires or emergencies rescuers cannot establish effective comms.
KINGTONE basement solution
Brings above-ground signal underground via fiber across multi-level garage.
View productNo fiber needed; quickly fixes local basement blind spots.
View productUp/down splitters + antennas for precise lane and zone coverage.
View productRemote monitoring of underground devices; auto alarm on dropout.
View productTypical project parameters
| Parameter | Reference value |
|---|---|
| Levels | 1–3 basement levels |
| Coverage area | 5,000–50,000 m² |
| Terminals | 20–100 units |
| Lead time | 3–10 working days |
Figures above are reference values from comparable projects; final configuration is subject to on-site survey and the contracted technical agreement.
Worked sizing: 2 basement levels, 12,000 m² each
- Scene sizing
- Two basement levels, 12,000 m² per level, 3.6 m clear height, 8.4 m column grid. A concrete slab adds roughly 25–35 dB of loss at 400 MHz, so outdoor signal does not reach parking bays or plant rooms on its own; security patrol, cleaning and fire drill teams talk at the same time.
- Design parameters
- One fiber BDA head-end with two remote units, ceiling antennas at 25–30 m spacing, about 16–20 antenna points per level. Design edge field strength no lower than −85 dBm, 4-core single-mode fiber backbone, optical budget calculated at 0.4 dB/km plus 2 dB connector margin.
- Acceptance
- At least 95% of test points in drive aisles and bays at or above −85 dBm; no blind spot in fire stairwells, plant rooms or lift lobbies; communication holds for at least 120 min after mains failure; no dropped call at ramps and entrances.
- Boundary
- Below 3,000 m² per level with usable outdoor signal, fiber is unnecessary — a wireless repeater is enough. Where slabs have no spare sleeves, survey the riser route first; core drilling can cost more than the equipment, so a cable-tray wireless route is the better answer.
These are design targets and the calculation method for a comparable project size, not measured results. Final configuration is subject to on-site survey and the contracted technical agreement.