SCENE / FACTORY

Smart Factory Radio Solution

Solves steel-structure attenuation, production/logistics/security cross-area coordination and open-yard blind spots, so production anomalies hit dispatch in seconds.

3 common smart-factory radio problems

  • 01

    Severe steel shielding:Large-span steel plants attenuate RF; single-site setup cannot cover the whole plant.

  • 02

    Production coordinated by shouting:Assembly, QA and warehouse communicate by running around; slow changeover and anomaly response.

  • 03

    Yard/loading blind spots:Open yards and dock aprons exceed plant coverage; logistics dispatch breaks.

KINGTONE smart-factory solution

Typical project parameters

ParameterReference value
Coverage area50,000–300,000 m²
GroupsProduction / Logistics / Security / Maintenance
Terminals100–800 units
Lead time20–60 working days

Figures above are reference values from comparable projects; final configuration is subject to on-site survey and the contracted technical agreement.

Worked sizing: 30,000 m² plant with 2 tower cranes

Scene sizing
A 30,000 m² site with four steel-structure workshops and one office building; two tower cranes with 60 m jibs and 45 m hook height; 180 terminals that must coexist with an existing analog system, and a line changeover that has to regroup radios within 10 minutes.
Design parameters
Two digital repeaters covering east and west zones; a directional antenna on each crane mast, tilted 8° down toward the lifting area; fiber BDAs inside workshops with antenna points at 30–40 m spacing; the dispatch console manages everything through the network-management platform, and analog-to-digital traffic crosses a gateway.
Acceptance
Clear-call rate between crane operators and ground banksmen at the jib tip no lower than 95%; workshop edge field strength at or above −85 dBm; no dropped call on zone handover; temporary regrouping completed and live within 10 minutes.
Boundary
Above 80 m hook height, lightning protection and feeder loss dominate — use fiber remote instead of long coax runs. Sites under 20 terminals do not need a digital repeater: analog radios with a same-frequency repeater are cheaper, and the money is better spent on antenna count and placement.

These are design targets and the calculation method for a comparable project size, not measured results. Final configuration is subject to on-site survey and the contracted technical agreement.

CASE FILE

Case brief

An equipment manufacturing park deployed RS3500 digital repeaters + CV120 fiber BDA + CV210 wireless broadband + S300 dispatch: coverage of plant, warehouse and open yard; production anomalies reach dispatch in seconds, logistics vehicle turnover improved.

Other scenario solutions

WhatsAppGet a Plan