FM Broadcast Repeaters
88–108 MHz and 150–152 MHz · +43 / +40 dBm · channel-selective
The TETRA and P25 product lines are not third-party certified yet. Where a project timeline allows, we can assess the certification path, lead time and cost against your specific band, power and interface requirements. If your tender explicitly requires existing certificates, tell us and we will be straight with you about what is feasible.
OEM private-label manufacturing and ODM design are both available. Regional distribution is not currently offered.
FM Broadcast Repeaters — what the line covers
Two FM broadcast products: a channel-selective rebroadcast unit for the 88–108 MHz broadcast band (6 channels, IP67) and a +40 dBm unit for the 150–152 MHz band. Used for single-programme re-broadcast, gap filling and regional coverage extension. Not third-party certified yet.
- 88–108 MHz (FM broadcast band)
- 150–152 MHz
+43 dBm / +40 dBm
- Off-air (RF)
Compatibility is stated for the cited model; confirm the exact combination against the model datasheet before ordering.
Models on this line
Parameters below are taken from the model datasheet. Where a figure has not been verified against the document body it is marked accordingly rather than estimated.
KT-A-M-BFMP43C-6
Internal model: KT-FMRP-CH6-P40
- Covers the full 88–108 MHz FM broadcast band, customizable
- 6-channel channel-selective operation
- +43 ± 2 dBm output, automatic level control within ±2 dB
- 95 ± 3 dB max gain with ≥ 30 dB adjustment range
- IMD ≤ −36 dBc — low intermodulation keeps programme audio clean
- Off-air RF coupling
Verified parameters and datasheet
| Frequency range | 88–108 MHz (customizable) | |
| Max output power | +43 ± 2 dBm (customizable) | |
| Channel number | 6 | |
| ALC | input +10 dB → ΔPo ≤ ±2 dB | |
| Max gain | 95 ± 3 dB | |
| Gain adjustable range | ≥ 30 dB | |
| Gain adjustable linearity | 10 dB → ±1.0 · 20 dB → ±1.0 · 30 dB → ±1.5 | |
| Ripple in effective band | ≤ 3 dB | |
| Max input level (1 min continuous) | −10 dBm | |
| Transmission delay | ≤ 5 µs | |
| IMD | ≤ −36 dBc | |
| Intermodulation 9 kHz–1 GHz | ≤ −36 dBm / 100 kHz | |
| Intermodulation 1–12.75 GHz | ≤ −30 dBm / 1 MHz | |
| Internal model | KT-FMRP-CH6-P40 | |
| IP rating / connectors / dimensions | Contact us for the full datasheet(to be confirmed) | |
Source file: FM 88-108MHz 10W Off-air Channel Selective Repeaters.pdf
KT-R-M-BF2P40B
Internal model: KT-FM-B20-P50-B
- 150–152 MHz band, nominal 2 MHz bandwidth
- +40 dBm output (45 W class)
- Group delay ≤ 5 µs and IMD control — programme audio stays clean
- Automatic level control holds output within ±1 dB at +20 dB input
- Off-air RF coupling
Verified parameters and datasheet
| Working frequency (nominal) | 150 – 152 MHz | |
| Bandwidth (nominal band) | 2 MHz | |
| Max output power | +40 dBm (FM modulating signal) | |
| Gain | 45 ± 3 dB | |
| ALC | input signal +20 dB → ΔPo ≤ ±1 dB | |
| Noise figure (in band, max gain) | ≤ 5 dB | |
| Ripple in band | ≤ 3 dB | |
| Frequency tolerance | ≤ 0.05 ppm | |
| Time delay (in band) | ≤ 5 µs | |
| Gain adjustment step | 1 dB | |
| Gain adjustment range | ≥ 30 dB | |
| Internal model | KT-FM-B20-P50-B | |
| Connector / IP rating / dimensions | Contact us for the full datasheet(to be confirmed) | |
Source file: Kingtone JIMTOM® FM 100W Repeater Data sheet.doc
How to read our model numbers
Every model encodes its standard, band, power tier, bandwidth type and coupling form. You do not need a lookup table to read it.
KT-{form}-{standard}-B{band}P{power}{bandwidth}[-{channels}]Every segment begins with an explicit letter (form, standard, B for band, P for power, C for channels), so position carries no meaning and a model cannot be misread. Multi-band cellular models list full 3GPP band codes (n28, B3, W8 …) rather than a shorthand, because procurement has to confirm the exact bands. Fibre systems add a unit role (-MU master / -RU remote) because the two are different units.
Models already covered by a third-party certificate keep their certified names — renaming them would break the certificate. A full one-page reference covering every code is supplied with the quotation on request.
Tell us the requirement, not the model
Send the band, power tier, bandwidth type, coupling form, channel count and project timeline. If certification is required for your tender, say so — we will tell you what is realistic rather than quoting a lead time we cannot meet.
Full datasheets for every model are available on request.