SCENE / RAIL TRANSIT

Railway & Metro Transit Radio Solution

Solves trackside and tunnelled coverage plus train-to-ground grouped dispatch for railways and metro: leaky feeder and fibre BDA carry signal through tunnels and viaducts, while IP-linked repeaters keep one logical group across section boundaries with no manual channel change.

3 common rail-transit radio problems

  • 01

    Tunnel and cutting black spots:Steel rail, tunnel lining and cuttings attenuate VHF/UHF; a single base station cannot hold continuous coverage along a line.

  • 02

    Section-boundary handoff:As a train crosses controller boundaries, off-air repeaters on different frequencies force drivers to retune mid-shift.

  • 03

    Train-to-ground isolation:moving trains lose dispatch contact; operations, maintenance and security cannot reach the driver or on-board crew.

KINGTONE rail-transit solution

Typical project parameters

ParameterReference value
Coverage formLeaky feeder in tunnel; fibre BDA at portals and open sections
Section handoffIP-linked repeater, no channel change on the move
GroupsOperations / Maintenance / Security / Emergency
Lead time45–120 working days (line-dependent)

Figures above are reference values from comparable projects; final configuration is subject to on-site survey and the contracted technical agreement.

Worked sizing: 6 km metro line, 8 stations, 2 depots

Scene sizing
6 km double-track line, 8 underground stations and 2 depots; tunnel sections dominate, with three above-grade viaduct stretches.
Design parameters
Leaky feeder sized per tunnel bore with 2 bidirectional amplifiers per section; fibre BDA at each portal using a 10–20 km optical run; RS3500 repeaters IP-linked so the driver group stays on one logical channel end to end; leaky-cable tap spacing set by measured coupling loss.
Acceptance
Field-strength floor checked at platform, tunnel and depot test points at ≤40 m spacing; handoff tested at every section boundary with zero dropped calls and no manual retune; same-frequency sites verified for ICS residual interference below the design threshold.
Boundary
Not for high-speed lines needing GSM-R / FRMCS or certified safety-to-train signalling — use the dedicated railway standard. Where a line has no existing leaky feeder and tunnelling is impossible, a off-air + fibre BDA hybrid is the fallback.

These are design targets and the calculation method for a comparable project size, not measured results. Final configuration is subject to on-site survey and the contracted technical agreement.

CASE FILE

Case brief

A metro extension used leaky feeder in the bored sections and CV120 fibre BDA at portals, with RS3500 repeaters IP-linked across all sections: operations, maintenance and security each held one group end to end; drivers crossed section boundaries without retuning, and the depot shared the same logical channel as the line.

Other scenario solutions

WhatsAppGet a Plan